smartctl version 5.38 [i686-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:    ST31000528AS
Serial Number:    9VP8W14V
Firmware Version: CC38
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:  8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Thu Oct 13 20:35:34 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.

General SMART Values:
Offline data collection status:  (0x82)        Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (  0)        The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                  ( 625) seconds.
Offline data collection
capabilities:                          (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003)        Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01)        Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:          (  1) minutes.
Extended self-test routine
recommended polling time:          ( 190) minutes.
Conveyance self-test routine
recommended polling time:          (  2) minutes.
SCT capabilities:                (0x103f)        SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG    VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate    0x000f  113  099  006    Pre-fail  Always      -      58214002
  3 Spin_Up_Time            0x0003  094  094  000    Pre-fail  Always      -      0
  4 Start_Stop_Count        0x0032  100  100  020    Old_age  Always      -      78
  5 Reallocated_Sector_Ct  0x0033  028  028  036    Pre-fail  Always  FAILING_NOW 2955
  7 Seek_Error_Rate        0x000f  085  060  030    Pre-fail  Always      -      372510161
  9 Power_On_Hours          0x0032  090  090  000    Old_age  Always      -      8873
 10 Spin_Retry_Count        0x0013  100  100  097    Pre-fail  Always      -      0
 12 Power_Cycle_Count      0x0032  100  100  020    Old_age  Always      -      39
183 Unknown_Attribute      0x0032  100  100  000    Old_age  Always      -      0
184 Unknown_Attribute      0x0032  100  100  099    Old_age  Always      -      0
187 Reported_Uncorrect      0x0032  099  099  000    Old_age  Always      -      1
188 Unknown_Attribute      0x0032  100  098  000    Old_age  Always      -      12885098499
189 High_Fly_Writes        0x003a  100  100  000    Old_age  Always      -      0
190 Airflow_Temperature_Cel 0x0022  057  048  045    Old_age  Always      -      43 (Lifetime Min/Max 42/47)
194 Temperature_Celsius    0x0022  043  052  000    Old_age  Always      -      43 (0 22 0 0)
195 Hardware_ECC_Recovered  0x001a  023  015  000    Old_age  Always      -      58214002
197 Current_Pending_Sector  0x0012  100  100  000    Old_age  Always      -      0
198 Offline_Uncorrectable  0x0010  100  100  000    Old_age  Offline      -      0
199 UDMA_CRC_Error_Count    0x003e  200  200  000    Old_age  Always      -      0
240 Head_Flying_Hours      0x0000  100  253  000    Old_age  Offline      -      104419244909318
241 Unknown_Attribute      0x0000  100  253  000    Old_age  Offline      -      1121468465
242 Unknown_Attribute      0x0000  100  253  000    Old_age  Offline      -      1129301566

SMART Error Log Version: 1
ATA Error Count: 1
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 8698 hours (362 days + 10 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 ff ff ff ef 00  33d+04:18:14.735  READ DMA EXT
  25 00 50 ff ff ff ef 00  33d+04:18:14.699  READ DMA EXT
  25 00 30 ff ff ff ef 00  33d+04:18:14.699  READ DMA EXT
  25 00 80 ff ff ff ef 00  33d+04:18:14.662  READ DMA EXT
  25 00 80 ff ff ff ef 00  33d+04:18:14.651  READ DMA EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline      Completed without error      00%      6954        -
# 2  Short offline      Completed without error      00%      6945        -
# 3  Short offline      Completed without error      00%      6945        -
# 4  Short offline      Completed without error      00%        5        -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.