nowy EG BestOf

Dysk z nowego EG BestOF zdechł po 12 godzinach – dodam ze wczoraj nie miał reallocated sectors i innych błędów.
Nie wiem czy to ja mam takiego pecha czy teraz nie ma co już liczyć na normalny serwer w OVH.

Kod:

# smartctl -a /dev/sdb
smartctl 5.40 2010-02-03 r3060 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:    Seagate Barracuda 7200.11 family
Device Model:    ST31500341AS
Serial Number:    9VS4KHE4
Firmware Version: CC1H
User Capacity:    1,500,301,910,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:  8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Fri Nov  5 13:06:30 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)        Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (  0)        The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                  ( 609) seconds.
Offline data collection
capabilities:                          (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003)        Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01)        Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:          (  1) minutes.
Extended self-test routine
recommended polling time:          ( 255) minutes.
Conveyance self-test routine
recommended polling time:          (  2) minutes.
SCT capabilities:                (0x103f)        SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG    VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate    0x000f  091  091  006    Pre-fail  Always      -      42361877
  3 Spin_Up_Time            0x0003  100  100  000    Pre-fail  Always      -      0
  4 Start_Stop_Count        0x0032  100  100  020    Old_age  Always      -      10
  5 Reallocated_Sector_Ct  0x0033  097  097  036    Pre-fail  Always      -      142
  7 Seek_Error_Rate        0x000f  100  253  030    Pre-fail  Always      -      258778
  9 Power_On_Hours          0x0032  100  100  000    Old_age  Always      -      22
 10 Spin_Retry_Count        0x0013  100  100  097    Pre-fail  Always      -      0
 12 Power_Cycle_Count      0x0032  100  100  020    Old_age  Always      -      10
184 End-to-End_Error        0x0032  100  100  099    Old_age  Always      -      0
187 Reported_Uncorrect      0x0032  077  077  000    Old_age  Always      -      23
188 Command_Timeout        0x0032  099  099  000    Old_age  Always      -      4295032833
189 High_Fly_Writes        0x003a  099  099  000    Old_age  Always      -      1
190 Airflow_Temperature_Cel 0x0022  061  061  045    Old_age  Always      -      39 (Lifetime Min/Max 37/39)
194 Temperature_Celsius    0x0022  039  040  000    Old_age  Always      -      39 (0 20 0 0)
195 Hardware_ECC_Recovered  0x001a  037  029  000    Old_age  Always      -      42361877
197 Current_Pending_Sector  0x0012  100  100  000    Old_age  Always      -      16
198 Offline_Uncorrectable  0x0010  100  100  000    Old_age  Offline      -      16
199 UDMA_CRC_Error_Count    0x003e  200  200  000    Old_age  Always      -      0
240 Head_Flying_Hours      0x0000  100  253  000    Old_age  Offline      -      25215752994838
241 Total_LBAs_Written      0x0000  100  253  000    Old_age  Offline      -      2900565463
242 Total_LBAs_Read        0x0000  100  253  000    Old_age  Offline      -      3187048857

SMART Error Log Version: 1
ATA Error Count: 23 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 23 occurred at disk power-on lifetime: 22 hours (0 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5f 09 00 00

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 3f 09 00 40 00      15:37:01.908  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      15:37:01.881  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      15:37:01.880  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      15:37:01.866  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      15:37:01.839  READ NATIVE MAX ADDRESS EXT

Error 22 occurred at disk power-on lifetime: 22 hours (0 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5f 09 00 00

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 3f 09 00 40 00      15:36:56.736  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      15:36:56.708  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      15:36:56.707  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      15:36:56.694  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      15:36:56.667  READ NATIVE MAX ADDRESS EXT

Error 21 occurred at disk power-on lifetime: 22 hours (0 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5f 09 00 00

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 3f 09 00 40 00      15:36:51.130  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      15:36:51.103  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      15:36:51.102  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      15:36:51.088  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      15:36:51.061  READ NATIVE MAX ADDRESS EXT

Error 20 occurred at disk power-on lifetime: 22 hours (0 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5f 09 00 00

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 3f 09 00 40 00      15:36:40.819  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      15:36:40.791  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      15:36:40.790  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      15:36:40.777  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      15:36:40.749  READ NATIVE MAX ADDRESS EXT

Error 19 occurred at disk power-on lifetime: 22 hours (0 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5f 09 00 00

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 3f 09 00 40 00      15:36:23.396  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      15:36:23.367  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      15:36:23.365  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      15:36:23.352  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      15:36:23.325  READ NATIVE MAX ADDRESS EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline      Completed without error      00%        5        -
# 2  Short offline      Completed without error      00%        0        -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.